EasyManua.ls Logo

USC LPH800 - MIX Tank, Calibration Tube

USC LPH800
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 21
LPH800 TREATER
MIX TANK
The LPH800 Treater includes a 30 gallon stainless steel chemical mix tank. This mix
tank will have electric drive agitation that is turned on or off from a manual switch.
The agitator should be running at all times when treatment is present in the mix tank to
keep the chemical mixed and in a suspended state. The tank is equipped with a
shut-off, drain plug, and drain valve located on the bottom. The top of the tank also
includes 3 extra ports which the operator can use to direct fill into the tank (see below).
CALIBRATION TUBE
The LPH800 Treater is equipped with a calibration
tube which is used to check the liquid flow rate.
The calibration tube measures in ounces, on a 0-340
scale and millimeters on a 0-10000 scale. Manual
valves direct liquid from different areas to keep all
liquid contained. This creates a closed chemical
system so that the operator can manually check the
calibration of the chemical flow rate without handling
any of the chemical.

Other manuals for USC LPH800