LPH800 TREATER
8. INLET CONVEYOR SWITCH:
This switch controls
the inlet conveyor in conjunction with a timer relay.
When the switch is turned on, the conveyor will run until
seed covers the proximity switch mounted near the top
of the supply hopper, at which time the conveyor will turn
off automatically. The inlet conveyor will remain off
until seed has dropped below the proximity switch.
A timer relay (right) will turn the conveyor back on after
a pre-determined time. The timer relay located inside
the control panel is set to Mode “A” and has an
adjustable knob with settings from 0-6. Each number
represents the number of seconds from the time the
proximity switch is uncovered to when the conveyor will
turn back on. The time delay prevents the conveyor
from turning on and off too quickly.
9. DRUM:
This switch allows the operator to turn the drum on or off.
10. ATOMIZER:
This switch allows the operator to turn the rotary driven atomizer on
or off for primary distribution of product on the seed. This switch must be turned on
before the seed treating process begins and before the pump(s) will operate in AUTO.
11. MIX TANK:
This switch allows the operator to turn the chemical mixer / agitator
on or off to allow for a perfectly mixed application of the seed treatment.
12) OUTLET CONVEYOR SWITCH:
This switch allows the operator to turn the outlet
conveyor on or off.