LPH800 TREATER
11. As soon as one minute is up, position the Calibration Valve back to
RECIRCULATE. Read the level on the side of the measuring cup. This number
should equal the number of ounces needed to flow through the pump in one
minute. If the ounces needed per minute have not been met, adjust the pump
speed up or down accordingly and repeat steps 9,10, & 11 until the liquid flow rate
has been matched.
Calibration Valve
Calibration Hose
PUMP #2 CALIBRATION