Page 47
LPH800 TREATER
ROTATING DRUM
1. Remove the shields and clean out any seed that may have fallen underneath the
drum.
2. Lubricate the chain to keep from corroding in storage.
LIQUID SYSTEM
1. Make certain the inside of the tank is completely drained of chemical residue and
thoroughly flush the inside of the tank with clean water.
2. Remove and clean the filter.
3. Pump clean water through all areas of the plumbing including the mix tank, flow
meter, and valves. It may be necessary to move the position of the air actuated
3-way valve from recirc to process in order to clean the chemical lines that run to
the seed treater.
4. Open all drain points, valves, and filter
to let as much of the liquid drain as
possible.
5. If the seed treater will be exposed to
possible freezing temperatures, the
final flush of the system should be
made with an non freezable liquid.
Or use compressed air to blow the
lines out from any moisture.
6. Release pump heads (right) and
remove tubing to prevent any
unnecessary wear.
Pump Head Open
FINAL
1. Store the machine inside a protective building to keep it from being exposed to the
weather.
2. Disconnect power to the machine.