Start-up 8
0020149486_04 auroFLOW plus Installation and maintenance instructions 23
8.4 Test menu
As well as the installation assistants, you can also call up the
test menu for start-up, maintenance and troubleshooting.
Menu Installer level Test menu
This contains Statistics, Check programmes and the
Sensor/actuator test.
8.4.1 Statistics
Menu Installer level Test menu Statistics
This displays the operating hours for:
Solar pump
Solar pump 2
Cylinder pump
8.4.2 Check programmes
Menu Installer level Test menu Check pro-
grammes
The following check programmes are available:
Test solar circuit filling
Start purging programme
8.4.3 Sensor/ actuator test
Menu Installer level Test menu Sensor/actuator
test
The current values of the following sensors can be read off
here:
T1 temperature sensor
T2 temperature sensor
T3 temperature sensor
T4 temperature sensor
T5 collector sensor
T6 cylinder sensor
Cylinder circuit flow rate
Temperature limiter
Solar circuit flow rate
The selection button can be used to activate the following
actuators. You can then use the plus and minus buttons to
change the output/power of the pumps, the flow direction
of the shift-load switching valve or the stratification in the
cylinder.
Solar pump
Solar pump 2
Cylinder pump
UV5 shift-load switching valve
In addition, you can view the approximate Solar circuit flow
rate. The value is calculated from the pump output and rota-
tional speed.
8.5 Configuration
You can use the menu Configuration to subsequently
change the settings that have been made using the
installation assistant.
Language
Contact details
Date
Time
Summer/winter time
Cascade
Number of collectors
In addition, the following information can be set or read:
Filling time correction
Mode
Heating flow set target temperature
Hot water set target temperature
Shift-load switching valve switch temperature
Maximum cylinder temperature
On temp. diff.
eBUS control
Filling power
Compensation time
Software version
8.5.1 Filling time correction
Menu Installer level Configuration Filling time
corr.
If the filling time is not sufficient for the solar circuit, the filling
time can be extended by up to ten minutes.
8.5.2 Mode
Note
If a system controller is connected, this menu
point does not appear.
Menu Installer level Configuration Operating mode
The operating mode can be set to Auto, High Flow and
Low Flow.
Auto: The solar control attempts to maintain the spread
between the solar supply pipe and the solar return so
that the process water zone in the cylinder is charged at
65 °C. If this is not possible due to low solar radiation, the
heating zone in the cylinder is charged at 40 °C. If this is
not possible either, a spread of 10 K is attempted.
High Flow: The solar control attempts to maintain the
spread between the solar supply pipe and the solar re-
turn at approx. 10 K. As a rule, this corresponds to 40 l/h
per m
2
collector surface
Low Flow: The solar control attempts to maintain the
spread between the solar supply pipe and solar return so
that the cylinder is charged at the maximum set cylinder
temperature. As a rule, this corresponds to 15 l/h per m
2
collector surface

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant auroFLOW plus VPM 15 D and is the answer not in the manual?

Vaillant auroFLOW plus VPM 15 D Specifications

General IconGeneral
BrandVaillant
ModelauroFLOW plus VPM 15 D
CategoryWater System
LanguageEnglish

Related product manuals