Display Meaning Display value/adjustable value
d.61 Number of fuel automatic system faults Number of successful ignitions in the last attempt
d.64 Average ignition time in seconds
d.65 Maximum ignition time in seconds
d.68 Successful ignitions in the first attempt Quantity
d.69 Successful ignitions in the second attempt Quantity
d.70 Set priority-changeover valve position 0 = Normal mode (factory setting)
1 = Centre position
2 = permanent heating position
d.71 Target value max. heating flow temperature
Adjustment range in °C: 40 to 85 (Factory setting: 75)
d.72 Pump return flow time after charging an electroni-
cally controlled hot water storage (also warm start and
charging through C1-C2)
Adjustment range in sec: 0, 10, 20 to 600
Factory setting for 800 series: 80
Factory setting for 600 series: 300
d.73 Offset for warm start target value (only 800 series) Adjustment range: -15 K to +15 K (Factory setting: 5 K)
d.75 Maximum charging time for a storage without own
controller
Adjustment range in min: 20, 21, 22 to 90 (Factory setting: 45)
d.77 Storage partial load (storage charging capacity limit) Adjustment range in kW: appliance-specific
Factory setting: max. output
d.78 Storage charging temperature limit (target flow tem-
perature in storage mode)
Adjustment range in °C 55 to 90 (Factory setting: 80)
d.80 Heating operating hours in h
d.81 Water heating operating hours (800 series only) in h
d.82 Hystereses in heating mode Quantity
d.83 Hystereses in hot water operation Quantity
d.84 Maintenance indicator: Number of hours until the next
maintenance
Adjustment range: 0 to 3000 h and “-”
Factory setting: “-” (300 corresponds to 3000 h)
d.93 DSN appliance variant setting Adjustment range: 0 to 99
d.95 eBus address Adjustment range (automatic scan)
d.96 Factory setting 1 = Resetting adjustable parameters to factory setting
Table 8.3 Diagnosis codes of the second diagnosis level (cont.)
8.1.3 Error codes
The error codes displace all other displays when errors
occur.
If many errors occur simultaneously, the relevant error
codes are displayed alternately for approx. 2 seconds
each.
8.1.4 Error memory
The last ten errors are saved in the appliance error
memory.
• Press the i” and “-” keys simultaneously.
Scroll back in the error memory with the “+” key.
You can exit the display of the error memory as follows:
• Press the i” key.
or
Do not press any key for about 4 minutes.
The current heating flow temperature appears in the dis-
play again.
Troubleshooting 8

Table of Contents

Other manuals for Vaillant ecoTEC plus SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus SERIES and is the answer not in the manual?

Vaillant ecoTEC plus SERIES Specifications

General IconGeneral
ModelecoTEC plus SERIES
MountingWall-mounted
Fuel TypeNatural Gas / LPG
ErP Heating Efficiency ClassA
NOx Class5
CategoryBoiler
TypeCondensing
EfficiencyUp to 94%
ErP Water Heating Efficiency ClassA

Related product manuals