EasyManuals Logo

Vaillant ecoTEC plus VU Series Installation And Maintenance Instructions

Vaillant ecoTEC plus VU Series
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12 Installation and maintenance instructions 0020308118_05
VUW 20/26 VUW 25/32 VUW 30/36
Gas flow rate for max. gas volume at 15 °C and 1013 mbar,
G20
2.80 m³/h 3.45 m³/h 3.88 m³/h
Nominal heat output range at 40/30 °C
2.9 to 21.7 kW 4.0 to 26.9 kW 4.3 to 32.9 kW
Nominal heat output range at 50/30 °C
2.8 to 21.2 kW 3.9 to 26.5 kW 4.2 to 32.2 kW
Nominal heat output range at 60/40 °C
2.6 to 20.3 kW 3.6 to 25.6 kW 4.0 to 31.1 kW
Nominal heat output range at 80/60 °C
2.5 to 19.8 kW 3.5 to 24.9 kW 3.7 to 29.9 kW
Max. heat input for heating
20.4 kW 25.5 kW 30.6 kW
Heating min. heat input
2.7 kW 3.7 kW 4.2 kW
Min. flue gas mass flow rate
1.23 g/s
(4.43 kg/h)
1.71 g/s
(6.16 kg/h)
1.94 g/s
(6.98 kg/h)
Max. flue gas mass flow rate
13.26 g/s
(47.74 kg/h)
15.75 g/s
(56.70 kg/h)
18.36 g/s
(66.10 kg/h)
Max. DHW heat output
DHW nominal heat input
26.5 kW 32.6 kW 36.7 kW
Nominal heat input range for heating
2.7 to 20.4 kW 3.7 to 25.5 kW 4.2 to 30.6 kW
Heating adjustment range
2.7 to 20.4 kW 3.7 to 25.5 kW 4.2 to 30.6 kW
VUW 30/40
Gas connection pressure, G20 natural gas
2.0 kPa
(20.0 mbar)
NOx emission, weighted, G20 (EN 15502-2-1)
26.30 mg/kWh
30% efficiency, G20
109.2 %
Gas flow rate for max. gas volume at 15 °C and 1013 mbar,
G20
4.32 m³/h
Nominal heat output range at 40/30 °C
5.2 to 32.9 kW
Nominal heat output range at 50/30 °C
5.0 to 32.3 kW
Nominal heat output range at 60/40 °C
4.8 to 31.2 kW
Nominal heat output range at 80/60 °C
4.5 to 29.8 kW
Max. heat input for heating
30.6 kW
Heating min. heat input
4.8 kW
Min. flue gas mass flow rate
2.22 g/s
(7.99 kg/h)
Max. flue gas mass flow rate
20.55 g/s
(73.98 kg/h)
Max. DHW heat output
DHW nominal heat input
40.8 kW
Nominal heat input range for heating
4.8 to 30.6 kW
Heating adjustment range
4.8 to 30.6 kW
Technical data G31 output/heat input (depending on the unit version)
VU 10 VU 15 VU 20
Gas connection pressure, G31 liquefied petroleum gas
3.7 kPa
(37.0 mbar)
3.7 kPa
(37.0 mbar)
3.7 kPa
(37.0 mbar)
NOx emission, weighted, G31 (EN 15502-2-1)
35.46 mg/kWh 28.04 mg/kWh 38.75 mg/kWh
Gas flow rate for max. gas volume at 15 °C and 1013 mbar,
G31
0.83 m³/h 0.83 m³/h 1.0 m³/h
Nominal heat output range at 40/30 °C
5.5 to 10.7 kW 5.5 to 16.1 kW 5.5 to 21.2 kW
Nominal heat output range at 50/30 °C
5.4 to 10.3 kW 5.4 to 15.4 kW 5.4 to 20.6 kW
Nominal heat output range at 60/40 °C
5.1 to 9.9 kW 5.1 to 14.8 kW 5.1 to 20.0 kW
Nominal heat output range at 80/60 °C
5.0 to 9.9 kW 5.0 to 14.8 kW 5.0 to 19.8 kW
Max. heat input for heating
10.2 kW 15.3 kW 20.4 kW
Heating min. heat input
5.2 kW 5.2 kW 5.2 kW
Min. flue gas mass flow rate
2.53 g/s
(9.11 kg/h)
2.53 g/s
(9.11 kg/h)
2.53 g/s
(9.11 kg/h)

Table of Contents

Other manuals for Vaillant ecoTEC plus VU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus VU Series and is the answer not in the manual?

Vaillant ecoTEC plus VU Series Specifications

General IconGeneral
TypeCondensing Boiler
InstallationWall-mounted
Heating circuitSealed System
ErP RatingA
FuelNatural Gas
EfficiencyUp to 94%
Modulation1:6
Warranty2-5 years (depending on model and region)
Dimensions720 x 440 x 338 mm