Installing the flue gas pipe on the external wall
Installation manual for the flue pipe for ecoTEC plus 0020137851_02 21
8
a
Danger!
Risk of injury due to falling parts!
Exceeding these dimensions can lead to
mechanical damage to the flue gas guiding.
In extreme cases, parts may become loose
from the wall and fall, thus endangering
persons.
> Observe the permitted height above the
flue gas pipe.
> Secure at least every second extension
to the external wall using a pipe bracket
a
Danger!
Risk of injury due to falling parts!
An offset reduces the tensile strength of
the flue gas guiding and can lead to rota-
tion or loosening of the flue gas guiding.
> Ensure that the part of the flue gas pipe
that protrudes above the roof is suffi-
ciently rigid.
> Do not install an offset between the two
uppermost pipe brackets (dimension C).
> Install air clamps at all connecting joints
between the two uppermost pipe brack-
ets (dimension C) and the uppermost
section (dimension D).
Max. 5 m
Max. 4 m
A
A
A
1
2
1
2
8.3 Static dimensions for an offset of the flue gas guiding
a
Danger!
Risk of injury due to falling parts!
An offset increases the risk that the
flue gas guiding will become loose or
twisted.
However, if an offset for the flue gas pipe
is required, always observe the following
precautions.
> Use 45° elbows.
> Only install one offset (
¬ Fig. 8.3).
> Observe the following dimensions:
- The length of the diagonally guided
section
must not exceed 4 m.
- The distance A between 2 pipe
brackets (1) must not exceed 1 m.
- The length of the vertical section
must not exceed 5 m.
> Connect the 45° elbows to the extension
on both sides using clamps (2).
8.3 Installing the flue gas pipe
8.3.1 Installation instructions
> When installing the flue pipe, observe the following infor-
mation:
a
Danger!
Risk of poisoning due to escaping flue
gas!
Mineral-oil-based greases can damage the
seals.
> Use only the supplied lubricant to facili-
tate installation.
> Lightly grease the seal and inserting
ends.
8.4 Greasing the seal and the inserting ends with lubricant
> Do not use any damaged seals.