User's Guide ______________________________________________________________________
108 _________________________________________________________________ M210455EN-B
In case of the "Optics Contamin" alarm (see Table 10 on page 51) the
window has to be cleaned.
To clean the window:
1. Flush the window with water to remove coarse grains.
2. Clean the window with a lens-cleaning wipe.
CAUTION
Particles between the towel and the window may damage the anti-
reflection coating. Therefore, instead of circular rubbing, the window
should be wiped once across the window. If additional wiping is
needed, a clean part of the towel should be used.
Storage
Place caps on all external connectors if stored unpacked for extended
periods of time in an unconditioned area. Also, maintain a dust cover
on the window during long periods of storage.
Logger Enclosure QME101M
Logger tube QME101M requires a minimal amount of maintenance.
Field repairs are accomplished by replacing the complete module.
Power Supply and Connection Unit QMP202MP
QMP202MP requires a minimal amount of maintenance. Field repairs
are accomplished by replacing the complete module. The expected
battery life expectancy is 4 to 5 years.
Mains Power Supply QMP211
QMP211 requires a minimal amount of maintenance. Field repairs are
accomplished by changing the complete module.
NOTE
Do not open the mains power supply unit.