EasyManua.ls Logo

Vaisala TACMET MAWS201MP - Table 10 List of Possible Alarms

Vaisala TACMET MAWS201MP
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 ________________________________________________________________ Operation
VAISALA _______________________________________________________________________ 51
Table 10 List of Possible Alarms
Alarm Explanation and Possible Remedy
CT25KAM: Comm. failure Communication failure. Verify correct cable
connections or replace sensor.
CT25KAM: HW alarm/warning Hardware error on CT25KAM.
CT25KAM: Optics contamin. CT25KAM optics contaminated. Clean the
optics.
QMP202MP: Battery low QMP202MP battery low. Connect
QMP202MP to an AC outlet.
AC (mains): Off QMP202MP is not connected to AC outlet.
PMT16: Air press. misg. Air pressure value missing. Not user
serviceable.
PWD11A: Comm. failure Communication failure. Verify correct cable
connections or replace sensor.
QMP202MP battery empty or hardware
failure.
PWD11A: HW alarm/warning Hardware error on PWD11A.
PWD11A: Optics contamin. PWD11A optics contaminated. Clean the
optics.
QMD101M: Comm. failure Communication failure. Verify correct cable
connections or replace handheld terminal.
QMH101M: Air temp. misg. Air temperature value missing. Verify
correct cable connections or replace
sensor.
QMH101M: Humidity misg. Humidity value missing. Verify correct
cable connections or replace sensor.
QMR101M: Rain gauge misg. Rain gauge missing. Verify cable
connections.
SA-20: Comm. failure Communication failure. Verify correct cable
connections or replace sensor.
SA-20: HW alarm/warning Hardware error on SA20M.
SA-20: Skinmap rate high Too much electrical interference. Remove
interfering equipment.
WS425: Wind dir. misg. Wind direction value missing. Verify correct
cable connections or replace sensor.

Table of Contents