TECHNICAL DATA
This chapter provides the technical data of the TACMET Weather
Station for Pole Mast Installations.
Polling/Reporting Times
Table 40 Sensor Polling/Reporting Times
Parameter Polling Reporting
Wind direction (WS425) 1 s 5 s
Wind speed (WS425) 1 s 5 s
Air temperature (QMH101M) 10 s 1 min
Relative humidity (QMH101M) 10 s 1 min
Air pressure (PMT16A) 10 s 1 min
Precipitation (QMR101M) 1 min 1 min
Lightning (SA20M) 5 s 5 s
Sky condition (CT25KAM) 30 s 30 s
Present weather (PWD11A) 30 s 30 s