not satisfactory disconnect the appliance and advise the customer of the cause
of failure.
13.3 Flame supervision and spillage monitoring system.
This pilot unit includes a system that will automatically shut off the gas supply if the
pilot flame goes out or if there is insufficient oxygen due to spillage or poor ventilation.
This monitoring system must not be adjusted, bypassed or put out of
operation.
This monitoring system or any of its parts must only be exchanged using Valor
Fires authorised parts.
14. FINAL REVIEW
1. COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICE SECTION
OF THE OWNER GUIDE (See last pages of the OWNER guide).
2. Visually inspect the appliance. Clean off any marks incurred during installation. The
fire should be OFF and allowed to cool completely before cleaning.
Metal and painted parts.
Clean the metal parts with a slightly damp lint free non-abrasive cloth and then
dry.
Do not use abrasive cleaners as these will scratch the fire surface.
3. Advise the customer how to operate the appliance. Point out that lighting
instruction details are contained in the owner guide. Explain to the customer that the
appliance has a flame failure & spillage monitoring system. Point out the explanation
of this system shown in the owner guide under “Operating the fire”. Advise that if the
fire goes out for any reason; wait at least three minutes before relighting. Stress that if
the monitoring system repeatedly shuts off the fire, the appliance should be switched
off and a specialist should be consulted.
4. Advise the customer that they should read their owner guide before operating the
fire and always follow the advice in the section headed “Cleaning your fire”.
5. Stress that no ceramic fuel effect pieces must be added to the appliance.
Warn that ignoring this advice could cause incomplete clearance of the
products of combustion with consequent health hazards.
6. Advise the customer that the appliance will operate to its maximum potential if the
flue is primed during the first 20 – 30 minutes of use. To do this, simply turn the
control to its ‘HIGH’ setting.
7. Recommend that the appliance should be serviced by a competent person at least
annually.
8. If the appliance is in premises in the United Kingdom occupied by a tenant, point
out that by law a landlord must have any gas appliance, flue and pipework which is
situated in a tenant’s premises checked for safety at least every 12 months.
Page 30
© Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE