EasyManua.ls Logo

VAT 670 Series - Installation Procedure

Default Icon
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION Series
670
14/39
Edition 2018-06-19 943070EA
4.2.3
Installation procedure
All numbers in brackets refer to chapter «Installation overview».
1. Remove protective covers from body flanges.
2. Install symmetrical flow valve [1] into the vacuum system. Refer to chapter «Installation
overview».
Do not tighten the flange screws stronger than indicated under «Tightening
torque».
Do not admit higher forces to the valve than indicated under «Admissible forces».
Make sure that enough space is kept free to do preventive maintenance work. The
required space is indicated on the dimensional drawing
3. Install actuator cables [2] to actuators and then to the External Controller IC2 [3]. Refer to chapter
«Installation overview».
Take care to the connector position at actuators, refer to 3 dots at connector for
correct connection.
4. Install all electrical connections at External Controller. Refer to «External Controller manual
(IC2)».
5. Connect VAT heating device [4] according to manual of respective heating device.