MAINTENANCE Series
670
20/39
Edition 2018-06-19 943070EA
7.2.1
Removing the plate and plate seal replacement
7.2.1.1 Required tools
Allen wrench 5 mm
O-ring removal tool
CPA 4.0 (in EC2 integrated)
Cleanroom wiper
Isopropyl alcohol
Clean room gloves
Electrical power is required.
Description Required tool
Use the CPA 4.0 which is
integrated in the IC2 controller.
1. Go to [LOCAL] mode.
CPA
2. Select position [20] = 20 % open.
CPA
If PFO available on IC2
controller, proceed with step 3,
if not go to step 4.
3. Disable the PFO in menu: Valve >
Parameters > Power Fail Option >
Enable = [False], press save button
or [Enter] on keyboard.
CPA