EMR
3
Setup and Operation Manual C&C Mode Setup Categories
32
DISPLAY SYNTAX
Figure 34 illustrates Display Syntax setup in C&C Mode. Table 1 shows the EMR
3
display syntax defaults.
Figure 34. Display Syntax Setup
Table 1 - EMR
3
Default Syntaxes
Item Default Syntax
Decimal Symbol 8,888.88
Thousands Symbol 88,888.8
Preset Res
Preset Volume 33,333.3
Preset Price 33.3333
Preset Currency 3,333.33
Register Res
Register Volume 33,333.3
Register Price 33.3333
Register Currency 3,333.33
Register Rate 333,333
Totalizer Res
Totalizer Volume 333 3333.3
Press ENTER to accept
choice
ENTER
ENTER ENTER
DECIMAL SYMBOL
THOUSNDS SYMBL
SELECT DEC SYM
NEXT
-
+
8888.88
8888,88
Press ENTER to accept
choice
ENTER
SELECT SYMBOL
NEXT
88.888.8
88,888.8
PRESET RES
Press ENTE
to accept
choice
ENTER
NEXT
888888
8.88888
88.8888
888.888
8888.88
88888.8
NEXT
NEXT
NEXT
NEXT
NEXT
-
+
PRESET VOLUME*
PRESET PRICE
PRESET CURENCY
REGISTER RES
Press ENTE
to accept
choice
ENTER
NEXT
888888
8.88888
88.8888
888.888
8888.88
88888.8
NEXT
-
+
REGISTER VOL*
REGISTER PRICE
REGISTER CRNCY
REGISTER RATE
TOTALIZER RES
Press ENTER to accept
choice
ENTER
NEXT
88888888
8888888.8
888888.88
NEXT NEXT
TOTALIZER VOL*
DISPLAY SYNTAX
TEMPERATURE
FUEL SOURCE
METER CALIBRTN
CONFIGURE I/O
OEM MESSAGE
DELIVERY OPTIONS
REPORT FORMATS
RESTART
SECURITY CODE
LANGUAGE
-
+
Press the up/down
buttons to cycle
through remaining
C/C Mode categories
NEXT
Note: to avoid rounding-off errors in totals, carefully choose
decimal point selections for PRESET RES and REGISTER RES
*NOTE: Decimal place choice for
TOTALIZER VOL can not exceed decimal
place selected in PRESET VOLUME or
REGISTER VOL.