Part No. 577013-767, Revision H 11
Function Code: 052 Version 1
Function Type: Start In-Tank Leak Detect Test
Command Format:
Display: <SOH>S052TT
Computer: <SOH>s052TT
Typical Response Message, Display Format:
<SOH>
S05201
22-05-01 14:55
TANK PRODUCT LABEL
1 REGULAR UNLEADED LEAK TEST START
TEST BY EXTERN INTERFACE
<ETX>
Typical Response Message, Computer Format:
<SOH>s052TTYYMMDDHHmmTTk&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00 = all)
3. k - Status Flag - 0 = OFF, 1 = ON
4. && - Data Termination Flag
5. CCCC - Message Checksum