Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 56
Function Code: 517 Version 1
Function Type: Set System Type & Language Flags
Command Format: Inquire:
Display: <SOH>S51700ULL <SOH>I51700
Computer: <SOH>s51700ULL <SOH>i51700
Typical Response Message, Display Format:
<SOH>
I51700
22-05-01 14:59
SYSTEM TYPE AND LANGUAGE FLAG
LANG : ENGLISH
UNITS : U.S.
<ETX>
Typical Response Message, Computer Format:
<SOH>i51700YYMMDDHHmmULL&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. U - System Units:
1 = U.S.
2 = Metric
3 = Imperial Gallons
3. LL - System Language:
01 = English
02 = French
03 = Spanish
04 = German
05 = Portuguese
06 = Polish
07 = Swedish
09 = Finnish
11 = Russian
12 = Turkish
14 = Italian
15 = Chinese
4. && - Data Termination Flag
5. CCCC - Message Checksum