Part No. 577013-767, Revision H 84
Function Code: 607 Version 1
Function Type: Set Tank Diameter
Command Format: Inquire:
Display: <SOH>S607TTIII.hh <SOH>I607TT
Computer: <SOH>s607TTFFFFFFFF <SOH>i607TT
Notes:
1. TT - Tank Number (Decimal, 00 = all)
2. III.hh - Tank Diameter, Inches and hundredths (Decimal)
3. FFFFFFFF - Tank Diameter, Inches (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I60701
22-05-01 15:07
TANK DIAMETER
TANK PRODUCT LABEL INCHES
1 REGULAR UNLEADED 96.00
<ETX>
Typical Response Message, Computer Format:
<SOH>i607TTYYMMDDHHmmTTFFFFFFFF
TTFFFFFFFF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00 = all)
3. FFFFFFFF - Tank Diameter, Inches (ASCII Hex IEEE float)
4. && - Data Termination Flag
5. CCCC - Message Checksum