Function Code: 609 Version 1
Function Type: Set Tank Thermal Expansion Coefficient
Command Format: Inquire:
Display: <SOH>S609TTc.cccccc <SOH>I609TT
Computer: <SOH>s609TTFFFFFFFF <SOH>i609TT
Notes:
1. TT - Tank Number (Decimal, 00 = all)
2. c.cccccc - Thermal Expansion Coefficient (decimal)
3. FFFFFFFF - Thermal Expansion Coefficient (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I60901
22-05-01 15:07
TANK THERMAL COEFFICIENT
TANK PRODUCT LABEL
1 REGULAR UNLEADED 0.000651
<ETX>
Typical Response Message, Computer Format:
<SOH>i609TTYYMMDDHHmmTTFFFFFFFF
TTFFFFFFFF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00 = all)
3. FFFFFFFF - Thermal Expansion Coefficient (ASCII Hex IEEE float)
4. && - Data Termination Flag
5. CCCC - Message Checksum