Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 87
Function Code: 60A Version 1
Function Type: Set Tank Linear Calculated Full Volume
Command Format: Inquire:
Display: <SOH>S60ATTGGGGGG <SOH>I60ATT
Computer: <SOH>s60ATTFFFFFFFF <SOH>i60ATT
Notes:
1. TT - Tank Number (Decimal, 00 = all)
2. GGGGGG - Full Height Volume, Gallons (Decimal)
3. FFFFFFFF - Full Height Volume, Gallons (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I60A01
22-05-01 15:08
TANK FULL VOLUME
TANK PRODUCT LABEL TANK PROFILE GALLONS
1 REGULAR UNLEADED 1 PT 10000
<ETX>
Typical Response Message, Computer Format:
<SOH>i60ATTYYMMDDHHmmTTFFFFFFFF
TTFFFFFFFF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00 = all)
3. FFFFFFFF - Full height volume (ASCII Hex IEEE float)
4. && - Data Termination Flag
5. CCCC - Message Checksum