F008
Error multi sensor commu-
nication
Additionalsensorsnotswitchedon
EMCinuences
No other sensor available
Checkwiringbetweenthesensors
Connect the sensors correctly and make
them ready for operation
F013
Sensor signals a fault
Erroronthecurrentinput/digitalinput
No valid measured value
Connectedinstrumentswithoutfunction
Check current input
Check connected instruments (Second-
aryinstrument)
F016
Adjustment data exchanged
Valuesofthemin.andmax.adjustment
exchanged
Correct adjustment data
F017
Adjustment span too small
The values of the min. and max. adjust-
ment are too close together
Correct adjustment data
F025
Invalidlinearizationtable
Wrongoremptylinearizationtable
(1074,1075,1080,1100,1106)
Wrongvalueinthelinearizationtable
(1143,1144)
Createlinearizationtable
Correctlinearizationtable
F030
Process value out of limits
Processvaluesarenotwithintheadjust-
ed measuring range
Repeat adjustment
F034
EPROMhardwareerror
Electronics defective Restart instrument
Exchanging the electronics
F035
EPROM data error
Error in the internal instrument commu-
nication
Carry out a reset
Exchanging the electronics
F036
Faulty program memory
Errorduringsoftwareupdate Repeatsoftwareupdate
Exchanging the electronics
F037
RAMhardwareerror
Error in RAM Restart instrument
Exchanging the electronics
F038
Secondary signals failure
Connection cable to the Secondary in-
strument interrupted
InstrumentnotdenedasSecondaryin-
strument
One of the Secondary instruments sig-
nals a failure
Check the connection cable to the Sec-
ondary instrument
DeneinstrumentasSecondary
Check Secondary instruments
F040
Hardwareerror
Instrumentdefective(1092,1126)
Temperatureoutsidethespecication
(1091)
Restart instrument
Exchanging the electronics
Cooltheinstrumentorprotectitwithiso-
lationmaterialagainstheat/cold
F041
Photomultiplier error
Error in the measured value recording Restart instrument
Exchanging the electronics
F052
Faultyconguration
Invalid parameter adjustment Carry out a reset