11
3 Product description
VEGAPULS 67 • Probus PA
36533-EN-170405
This operating instructions manual applies to the following instrument
versions:
Hardware from 2.1.1
Software from 4.5.0
The scope of delivery encompasses:
Radar sensor
Mounting strap with xing material (optional)
Documentation
Quick setup guide VEGAPULS 67
Instructions for optional instrument features
Ex-specic "Safety instructions" (with Ex versions)
If necessary, further certicates
DVD "DTM Collection", included therein
PACTware
DTM Collection
Instrument master les (GSD) for Probus PA
FDT certicates
Information:
The optional instrument features are described in the operating
instructions manual. The respective scope of delivery results from the
order specication.
3.2 Principle of operation
The VEGAPULS 67 is a radar sensor for continuous level measure-
ment of bulk solids under simple process conditions. It is suitable for
smaller silos and vessels.
The instrument is also suitable for applications in liquids.
The antenna of the radar sensor emits short radar pulses with a
duration of approx. 1 ns. These pulses are reected by the product
and received by the antenna as echoes. The transit time of the radar
pulses from emission to reception is proportional to the distance and
hence to the level. The determined level is converted into an appropri-
ate output signal and outputted as measured value.
3.3 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging of standard instruments consists of environment-
friendly, recyclable cardboard. For special versions, PE foam or PE
foil is also used. Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out in due consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
Scope of this operating