5
x
Speed Range
(steps/sec.)
1
2
3
4
5
6
1 -1000
1 -2000
1 -3000
1 -4000
1 -5000
1-6000
11
1000-2000
12
1000-3000
13
1000-4000
14
1000-5000
15
1000-6000
21
2000-3000
22
2000-4000
23
2000-5000
24
2000-6000
31
3000-4000
32
3000-5000
33
3000-6000
41
4000-5000
42
4000-6000
51
5000-6000
Table for analog assigned motor speed
lst
isstoredinaprogram,theoriginalxvaluewillbekeptwiththe
command. However,whenthe commandisusedtolisttheprogram,thexvalue
displayedwillbethesteps/secspeedconvertedfromreadingAin.
ThisfeatureallowsviewingtheactualderivedspeedtheVXMis
goingtouse.
NOTE: WhenaSmM-x
+5V (I/O,2)
0V (I/O,1)
Ain(I/O,3)
2Kto10KOhmPotentiometer
(5Krecommended)
Connection to Potentiometer