Appendix M
Advanced Motor Setup
6
TheVXMappliesenergytothemotorsbasedonthesizeofthemotor. Thephysicalsize
istheimportantaspectthatdeterminestheamountenergytheVXMwillapply. Thesize
ofthemotorisproportionaltothemotor’scurrenttimesit’sinductance.
MotorsofthesamecurrentarenotthesametotheVXM. Whenusingmotorsnotlisted
forusewiththeVXM,settheVXMtomotorsettingthathasthesameorhighercurrent
timesinductancevaluethanthemotoryouwishtouse.
setmotortype/sizeselectedforaxismandapplies100%powerto
motorinjogmode(normally70%power), =axis#(1,2,3,4.)
Valueforxshould beanumberbetween0and6. Refertothetablebelowfor
thepropervaluetouse.
The100%motorpower
settingonlyappliestooperationinjogmode. Under
programcontrolthe“S”and“SA" speedsettingsset powertomotor.
m
NOTE:
CAUTION: THE VXM MUST BE SET TO THE EXACT MODEL/TYPE MOTOR(S)
BEFORE OPERATING. IMPROPER SETTINGS CAN CAUSESEVERE
DAMAGE TO MOTORSAND CONTROLLER.
SeeAlso
setMmMx, getMmM
x MotorModel(Amps)
0
1
Default(0.4Ato$
VextaPK245 $
2
3
Slo-Syn0061 $
Slo-SynM062 $
VextaPK264$
4
Slo-SynM063 $
VextaPK266$
5
Slo-SynM091 $
VextaPK268$
6
Slo-SynM092 (4.6A)
9H[WD3.$
VHW0$P0[