SERVICE
Service - 63
WARNING
An improperly adjusted neutral switch can result in
erratic engine cranking or unsafe power unit move-
ment. Check the neutral switch position after any
adjustment is made to the neutral position.
If the neutral switch needs to be checked or adjusted,
contact an authorized Ventrac dealer.
Storage
Preparing the Power Unit for Storage
1. Clean the power unit.
ATTENTION
To maintain the nish of the power unit, thoroughly
wash the equipment to remove any corrosive
agents (e.g., salt). Failure to clean the equipment
may result in corrosion of (including but not limited
to) steel, aluminum, and electrical components.
2. Inspect for loose or missing hardware, damaged
components, or signs of wear. Repair or replace
any damaged or worn components.
3. Inspect the ROPS structure and seat belt for signs
of damage or wear.
4. Inspect the safety decals. Replace any decals that
are faded, illegible, or missing.
5. Inspect the hydraulic hoses and ttings for leaks
and/or wear. Service as required.
6. Inspect the fuel lines for leaks.
7. Perform the parking brake inspection.
8. Inspect the electrical system and connections.
9. Test the operator safety interlock system.
10. Inspect the PTO pulley and belt for damage or
excessive wear. Service as required.
11. Perform the PTO clutch air gap inspection.
12. Check the hydraulic oil level. Add uid or service
as required.
13. Clean the engine compartment, the engine, and
the engine oil cooler.
14. Check the tires for proper ination.
15. Grease or lubricate all points specied in the
Lubrication section. Wipe o any excess grease or
oil.
16. Inspect the painted components for chips,
scratches, or rust. Clean and touch up the sur-
faces as needed.
After all the above steps have been performed, com-
plete the preparation for storage by performing the
steps for either long term storage (four months or
longer) or short term storage (less than four months).