Liebert PCW - UM - 273895 - 04.10.2018
Digit Nomenclature
The unit is fully dened by twenty ve digits.
1
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
65432
PH
7
Digit 16 - Colour
1 Black Vertiv RAL 7021
Digit 17 - High Voltage Option
D Standard Power Supply
F Dual Power Supply Parallel
G Dual Power Supply Alternate Basic
H Dual Power Supply Alternate Premium
5 Standard Power Supply + Condensate Pump
Q Dual Power Supply Parallel + Condensate Pump
M Dual Power Supply Alternate Basic + Condensate Pump
P Dual Power Supply Alternate Premium + Condensate Pump
Digit 18 - Option Package
0 None
S Smart Aisle (Predisposition for damper, Sensors, 3 position
switch)
F Economizer (sensors, predisposition for dampers)
G Smart Aisle + Economizer
Digit 19 - Monitoring
0 Monitoring - with IS Housing (No IS Card included)
N NO Intellislot Housing included
P Intellislot Unit Card for Modbus, BacNet, SNMP and Web
C Intellislot Sitescan Card (IS-485EXI)
Digit 20 - Sensors (Chilled Water Kit)
0 None
W Water Temperature Sensors IN / OUT
V Water Temperature Sensors & ow meter
Digit 21 - Packaging
P PLP And Pallet
C Cardboard and Wooden Crate
S Seaworthy
Digit 22 - Special Requirements
A Standard Vertiv
X Special Vertiv
Digit 8 - Airow
L Liebert EC Fan 2.0
1 EC Fan Fix Speed
Digit 9 - Main Power Supply
3 Single 400V / 3 ph / 50 Hz + N
Digit 10 - Valve
2 CW Two way Valves Standard Pressure
3 CW Three way Valves Standard Pressure
1 CW Two way Valves High Pressure
T CW Three way Valves High Pressure
V CW Two way Valves 0-10 V
W CW Three way Valves 0-10V
Digit 11 - Humidication
0 None
H Infrared Humidier
U Ultra Sonic
S Electrode humidier
Digit 12 - Microprocessor Control
2 Inner Display only T sensor
3 Inner Display TH sensor
U Small Cold re display T sensor
B Small Cold re display TH sensor
C Large Cold re display T sensor
D Large Cold re display TH sensor
W Small Cold re display T sensor (for PHxxxDL)
X Small Cold re display TH sensor (for PHxxxDL)
Y Large Cold re display T sensor (for PHxxxDL)
Z Large Cold re display TH sensor (for PHxxxDL)
Digit 13 - Heating & Re- Heating
0 None
1 Electric heating Std 1 Stage
2 Electric heating Opt. 2 Stage
4 Hot Water Heating
8 El. Heating + hot water coil
Digit 14 - Air Filter E󰀩ciency
1 F5 (EU5) dust spot
3 F5 (EU5) dust spot + Clogged Filter
Digit 15 - Coil (and Pipes)
H Standard Piping Bottom
T Standard Piping Top
S Standard Piping Left
Digit 1 and 2
PH Liebert PCW
Digit 3, 4 and 5
Unit Model
Digit 6 - Air Discharge
U Upow
H Downow Frontal
D Downow Up
E Downow Down
Digit 7 - System Type
L Chilled Water Extended Height
C C Chilled Water Standard Height
X Dual Source CW Extended Height
R Dual Source CW Standard Height