touch the surface of the mirror directly. Avoid pressing too hard to grind any
debris and cause scratches. If the mirrors are removed for cleaning,
reinstall them by rotating them clockwise into place while being careful to
avoid any scratches.
4.LASER PATH ALIGNMENT.
Proper beam alignment is very important for the overall efficiency and
quality of work of the machine. This machine is fully beam aligned before
shipment. However, when the engraver first arrives, approximately once a
week during normal operation, the user is advised to confirm that the
alignment is still at an acceptable level and that the mirror and focusing
lens are not moving due to the movement of the machine.
You'll need to place a piece of tape at each stage of the laser path, marking
it to confirm that the platform remains properly aligned. If not, you will use
the bracket of the laser tube or the screws on the back of the misaligned
mirror to correct the problem. Once the supplied tapes run out, we
recommend using masked tapes as it is easy to manage and use.
If beam alignment is performed carelessly, the operator may be exposed to
a small amount of radiation. Follow these procedures correctly and always
be careful when performing beam alignment.