CUTMASTER 35MM
Manual 0-5082 INTRODUCTION
2-3
2.05 Input Wiring Specifications
CutMaster 35mm Power Supply Input Cable Wiring Requirements
Input voltage Freq Power Input Suggested Sizes
Volts Hz kVA I max I eff
Fuse
(amps)
Flexible Cord
(Min. AWG)
Flexible Cord
(Min. mm
2
)
3
Phase
380 50 18.4 28 25 32 10 6
400 50 18.7 27 24 32 10 6
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired
installations refer to local or national codes.
I
1
max is taken at TDC rated minimum duty cycle.
I
1
eff is taken at TDC 100% rated duty cycle.