ATTENTION: All devices constituting hydromassage system are one-phased powered with ~230 V; 50 Hz
current.
Overcurrent switch B16
of pole number equal = number of phases + N
Cabin must be connected with use of a differential switch of In=0,03A.
It can be realised as overcurrent switch with differential module.
Power supply from 2 or accordingly 3 phases is preferable it can be also connected into existing one-phase
installations ( but this is not recommended by producer TECHNIC INDUSTRY, due to too high power )
by connecting phase wires of bath power lead with phase wire of power lead accordingly higher overcurrent
protection must be applied.
WARIANT
MAXIMUM
POWER
OVERCURRENT
PROTECTION
POWER LEAD
in electric
installation
1
2
3
4
1 Phase
3 Phases
3 Phases
3 Phases
B16
B16 / Phase
C16 / Phase
C16 / Phase
2
3x2,5 mm
2
5x2,5 mm
2
5x2,5 mm
2
5x2,5 mm
15
ENGLISH
CONNECTION
METHOD
2135 W
7950 W
9405 W
9415 W
Cabins power consumption
CABIN
MAXIMUM
POWER
ORINOCO
MISSISSIPI
AMAZON
CASSIOPEIA
3500 W
2700 W
3500 W
3500 W
Galapagos power consumption