The following table includes recommended by TECHNIC INDUSTRY
method of connecting a bathe into electric installation depending on
hydromassage system (and in specific cases – bath model) as well as required
overcurrent protection resulting from power input.
ATTENTION: All devices constituting hydromassage system are one phased
powered with ~230 V; 50 Hz current.
SYSTEM
MAXIMUM
POWER
CONNECTION
METHOD
POWER LEAD
in electric
installation
OVERCURRENT
PROTECTION
OVS-01 (A,B) 1000 W 1 PHASE B 16
2
3 x 2,5 mm
OVS-01 (A,B)
LANZAROTE, SINGAPORE
2000 W 1 PHASE B 16
2
3 x 2,5 mm
OVS-02 (A)
3800 W
1 PHASE
B 16
2
3 x 2,5 mm
OVS-02 (A) WITH A
HEATER 2700W
OVS-02 (A)
LANZAROTE, SINGAPORE
OVS-02 (A) WITH A
HEATER 2700W
LANZAROTE, SINGAPORE
OVS-03 (A)
OVS-03 (A) WITH A
HEATER 2700W
OVS-03 (A)
LANZAROTE, SINGAPORE
OVS-03 (A) WITH A
HEATER 2700W
LANZAROTE, SINGAPORE
2200 W
1100 W
4900 W
2100 W
4800 W
4200 W
6900 W
2 PHASES
1 PHASE
1 PHASE
2 PHASES
1 PHASE
1 PHASE
2 PHASES
1 PHASE
2 PHASES
1 PHASE
3 PHASES
B16 / phase
B 25
B 16
B16 / phase
B 25
B 16
B16 / phase
B 25
B16 / phase
B 25
B16 / phase
2
4 x 2,5 mm
2
3 x 4 mm
2
3 x 2,5 mm
2
4 x 2,5 mm
2
3 x 4 mm
2
3 x 2,5 mm
2
4 x 2,5 mm
2
3 x 4 mm
2
4 x 2,5 mm
2
3 x 4 mm
2
5 x 2,5 mm
ELECTRIC INSTALLATION PROTECTION AND A BATH
CONNECTING METHOD
8
ENGLISH