Please file in Service Binder
for use by heating contractor
5461 889 - 16 01/2019
Installation Instructions
Vitodens 222-F, B2TB
Models 19, 35, 68, 125
Floor mounted, gas-fired condensing storage combi boiler
For operation with natural gas and liquid propane gas
Heating input: 12 to 125 MBH
3.5 to 37 kW
VITODENS
r
222-F
Read and save these instructions
for future reference.
Product may not be exactly as shown
IMPORTANT
H

Table of Contents

Questions and Answers

  • U
    usalazarAug 30, 2025
    What causes fault code C3 on a Viessmann B2TB004 Boiler?
    • M
      Mrs. Barbara RoseAug 30, 2025
      If your Viessmann Boiler displays fault code C3, it indicates an Extension AM1 communication error. Check electrical connections.
  • W
    whillAug 25, 2025
    What to do if Viessmann B2TB004 displays fault code A9?
    • M
      Michael RiggsAug 25, 2025
      If your Viessmann Boiler displays fault code A9, it indicates that the internal circulation pump is blocked. You should check the circulation pump.
  • D
    David LynchSep 23, 2025
    What does error code E5 mean on a Viessmann B2TB004 Boiler?
    • N
      newmanrobertSep 23, 2025
      If your Viessmann Boiler displays error code E5, it indicates a fault with the flame amplifier. To resolve this, replace the control unit.
  • C
    Christian SalazarSep 2, 2025
    What does fault code dE mean on Viessmann B2TB004?
    • C
      Charles JohnsonSep 2, 2025
      If your Viessmann Boiler displays fault code dE, it indicates a lead break in the room temperature sensor, heating circuit 2 (with mixer). Check room temperature sensor for heating circuit 2 and remote control settings.
  • C
    Carol EricksonSep 6, 2025
    What does Fault Code b0 mean on my Viessmann B2TB004 Boiler?
    • R
      rebeccasmithSep 6, 2025
      If your Viessmann Boiler displays Fault Code b0, there is a short circuit in the flue gas temperature sensor. Check the flue gas temperature sensor.
  • S
    Stephen CarlsonAug 31, 2025
    How to fix fault code CF on Viessmann Boiler?
    • J
      Joseph FrySep 1, 2025
      If your Viessmann Boiler displays fault code CF, it indicates a communication error with the LON communication module. Replace the LON communication module.
  • J
    Judy BennettAug 28, 2025
    What causes fault code A7 on a Viessmann B2TB004?
    • H
      Howard DunnAug 28, 2025
      If your Viessmann Boiler displays fault code A7, it means the programming unit is faulty. Replace programming unit.
  • D
    David BondSep 8, 2025
    What does Fault Code E3 mean on my Viessmann B2TB004 Boiler?
    • C
      Christopher KirbySep 8, 2025
      If your Viessmann Boiler displays Fault Code E3, heat transfer is too low during calibration, and the temperature limiter caused a shutdown. Ensure adequate heat transfer and press the reset button R.
  • J
    johnjohnsonSep 4, 2025
    What does Fault Code b1 mean on my Viessmann B2TB004 Boiler?
    • C
      Cynthia YoderSep 4, 2025
      If your Viessmann Boiler displays Fault Code b1, this indicates a communication error with the programming unit. You should check the connections and replace the programming unit if necessary.
  • G
    griffinkirstenAug 27, 2025
    Why is my Viessmann Boiler showing fault code 30?
    • G
      Gary WattsAug 27, 2025
      If your Viessmann Boiler displays fault code 30, this indicates a short circuit in the boiler water temperature sensor. Check the boiler water temperature sensor.