EasyManua.ls Logo

Viessmann B2TF - Specification Specification

Viessmann B2TF
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
116
Gas boiler, type B and C, category II
2N3P
Type B2TF
Rated heating output range (details to EN 15502)
T
F
/T
R
= 50/30 °C (P(50/30))
Natural gas kW 1.9 - 19 1.9 - 25 1.9 - 32
LPG kW 2.5 - 19 2.5 - 25 2.5 - 32
T
F
/T
R
= 80/60 °C (Pn(80/60))
Natural gas kW 1.7 - 17.5 1.7 - 23 1.7 - 29.3
LPG kW 2.2 - 17.5 2.2 - 23 2.2 - 29.3
Rated heating output for DHW heating
Natural gas kW 1.7 - 22 1.7 - 28.6 1.7 - 33.9
LPG kW 2.2 - 22 2.2 - 28.6 2.2 - 33.9
Rated heat input (Qn)
Natural gas kW 1.8 - 17.8 1.8 - 23.4 1.8 - 29.9
LPG kW 2.3 - 17.8 2.3 - 23.4 2.3 - 29.9
Rated heat input for DHW heating (Qnw) kW 22.7 29.5 34.9
Product ID CE-0085CT0017
IP rating to EN 60529 IP X4
In conjunction with assembly kit (accesso-
ries)
IP X1
Protection class I
NO
X
Category 6
Gas supply pressure
Natural gas mbar
kPa
20
2
20
2
20
2
LPG mbar
kPa
50
5
50
5
50
5
Max. permiss. gas supply pressure
*3
Natural gas mbar
kPa
25.0
2.5
25.0
2.5
25.0
2.5
LPG mbar
kPa
57.5
5.75
57.5
5.75
57.5
5.75
Sound power level
(to EN ISO 15036-1)
At partial load dB(A) 38.8 38.8 38.8
At rated heating output (DHW heating) dB(A) 49.2 50.7 52.6
Power consumption in the delivered condi-
tion (incl. circulation pump)
W 54 68 110
Rated voltage V 230
Rated frequency Hz 50
Appliance fuse protection A 6.3
Backup fuse (power supply) A 16
RF module (integral)
WiFi frequency band MHz 2400 - 2483.5
Max. transmitting power dBm 17
Low power radio frequency band MHz 2400 - 2483.5
Max. transmitting power dBm 6
*3
If the gas supply pressure is higher than the maximum permissible value, install a separate gas pressure governor up-
stream of the system.