60
897.0 "Screed drying"
Setting Explanations
Not active 0 Screed drying can be set in accordance with selecta-
ble temperature/time profiles. For individual profile
curves, see chapter "Function description".
Diagram 1 2
Diagram 2 3
Diagram 3 4
Diagram 4 5
Diagram 5 6
Diagram 6 7
912.0 "Automatic summer/wintertime changeover"
Setting Explanations
No 0 Automatic changeover disabled
Yes 1 Automatic changeover enabled
912.1 "Earliest day of changeover from winter to summertime"
Setting Explanations
25 Changeover from 02:00 h to 03:00 h occurs on the
Sunday after or on this set date.
1 to 31 Day of changeover adjustable from 1st to 31st of the
month
912.2 "Month of changeover from winter to summertime"
Setting Explanations
3 Month of changeover: March
1 to 12 Month of changeover adjustable from January to De-
cember
912.3 "Earliest day of changeover from summer to wintertime"
Setting Explanations
25 Changeover from 03:00 h to 02:00 h occurs on the
Sunday after or on this set date.
1 to 31 Day of changeover adjustable from 1st to 31st of the
month
912.4 "Month of changeover from summer to wintertime"
Setting Explanations
10 Month of changeover: October
1 to 12 Month of changeover adjustable from January to De-
cember
1098.4 "Gas volume correction factor"
Setting Explanations
Value is provided on the gas supplier's bill.
Used for gas consumption data.
1.0000
0.7000 to
1.0000
Gas volume correction factor adjustable from 0.7000
to 1.0000 in increments of 0.0001.
System configuration (parameters)
General (cont.)
6151778
Parameter