Switch back to the index card.
index card 8:
This index card is intended for the
cancellation commands of a route.
After the train has passed the route, you
can cancel her and open the track sections
for the next train.
The elements the route is composed of
(turnouts and signals) have to be switched
back to their initial position. Refer to the
procedure described in the index card 5.
index card 9:
By this index card you set up the route
locking (ank protection).
For reasons of safety different routes can
not be switched at the same time (e. g. exit
tracks running parallel in the station and
leading to the same main track).
The Commander denes automatically
which routes should be locked in case that
they explore the same feedback modules.
In case of conicting routes not using the
same feedback modules you can program
the reciprocal interlocking manually.
• When the entries are done in all index
cards, save the route and close the edi-
tor by pushing the “Exit”-key.
You can call up again the route by ente-
ring the route number in the route editor
and modify the inputs.