13
Electrical connections
5777744-03 GB Subject to technical changes!
4.19 Mechanical work on the door or porthole
DANGER!
Risk of death due to electric
shock from damaged wires!
f Do not conduct any mechanical
work
(suchasdrillingorsawing)onthe
inside or outside of the door or port-
hole in the safety zone (1).
L
100 mm
100 mm
Electrical components are foamed in place in the
grey-marked safety zone 1. Damage to the electrical
components or wires poses the risk of electric shock.
 Observe safety zone (1)beforecommencingme-
chanical work on the door or porthole.
 Makes sure that mechanical work will only be con-
ducted outside of the safety zone.
4.20 Rearranging the luminaries
L
12
Moisture-proof luminaries and junction box are mount-
ed at the factory on the inside of the door frame.
L
The junction box with luminaries can be displaced by
90°.
 Pull the luminary (1)fromthemountingplate(2).
 Removetheplugfromthepre-punchedxingholes.
 Fasten mounting plate in its new position.
 Clip luminary to mounting plate.
5 Electrical connections
DANGER!
Risk of death due to electric
shock!
f Only have work for the mains
connection and installation of protec-
tivemeasures(GFCIcircuitbreaker)
conducted by a specialised electrical
contractor.
f Observe the applicable regula-
tions(EN,ISO,VDE,etc.)andcon-
nection conditions from the relevant
energy supply company.
DANGER!
Risk of death due to electric
shock!
f Before establishing the mains
connection, shut off the mains power
and secure it to prevent it from being
turned back on.