15
Decommissioning
5777744-03 GB Subject to technical changes!
Elements with a powder-coated sheet steel or
stainless steel surface:
 Do not spray-clean the inside or outside of the walls,
ceilings, elements with electrical components (such
asdoorframe)andunitwithwater.
 Wipe out the inside of the room, dry it completely
and air it out well.
 Do not use any scouring agents or cleaning agents
that contain solvents.
 Wipe the outside of the room with a damp cloth and
dry it off.
Standard oor:
 Wipe with damp cloth only.
 Donotcleanstandardoorswithwaterjet.
 Makesurethereisnowateronstandardoors.
Tub oor:
 Wipe with damp cloth only.
 Onlyexposetuboortostandingwaterorwaterjet
for a short amount of time.
For all oors:
 Regularly wash off door seals with neutral soap
solution and dry them off.
 Do not use acetone or cleaning agents that contain
solvents to clean the seals.
 Treatstainlesssteelroomoorwithstandardcom-
mercial stainless steel cleaning agents.
 Seal stainless steel surface with stainless steel care
product.
 Observe product information on cleaning agents.
8 Decommissioning
For prolonged downtime:
 Pull the power plug or shut off the mains power.
 Ensure adequate ventilation.
9 Technical data
9.1 Permissible loading on oor elements
Load
Weight
Class
Wheel Wheel Load (N**) Wheel
Load (N/
m
2
)
1 - 4 cm
2
> 4 cm
2
1. Rubber 400 1.600 30.000
2. PU-/Rubber 750 3.000 40.000
3. PU-/Rubber 1.000 4.000 50.000
4.* PU-/Rubber 1.250 5.000 50.000
*LoadWeightClass4)Specialversionfor5.000Noor:Extensionofapproval
up to 6.000N possible after interal check.möglich nach interner Prüfung
**10N≈1Kg
10 Maintenance
DANGER!
Risk of death due to electric
shock!
f Ensure that maintenance work
is carried out exclusively by trained
qualiedpersonnel.
f Disconnect power plug and se-
cure to prevent reconnection before
carrying out maintenance work.
 Conduct maintenance on TectoCell cold rooms and
deep-freezing rooms at least once per year.
 You can reach our technical customer service at:
+49 9281 814 908
11 Disposal
 Dispose of defective TectoCell cold rooms and
deep-freezing rooms in an environmentally friendly
manner according to applicable disposal regula-
tions.
12 Standards and laws
 Comply with the applicable standards and laws:
EMC directive 2014/30/EG
Machinery Directive 2006/42/EC, DIN EN 378
(2008/2012)