14
Central heating/central cooling
■
Standard room temperature ("Set room tempera-
ture"): see page 17.
Select your individual preferred temperature in the
standard menu at any time.
■
Preferred heating/cooling circuit: see page 49.
If your heating system comprises several heating cir-
cuits, you can input the important settings for a pre-
ferred heating/cooling circuit directly in the standard
menu.
■
Time program: see page 27.
Make use of the time program. In the time program,
you can set time phases with different room temper-
atures, for example different temperatures for day
and night time.
■
Heating water buffer cylinder (if installed): see
page 27.
Set the time program for the heating water buffer cyl-
inder so there is always sufficient heat for your heat-
ing circuits, for example to bridge power-OFF times
imposed by your local power supply utility.
■
Electric booster heater (if installed): see page 37.
Enable the electric booster heater. Set the time pro-
gram for this. The electric booster heater starts auto-
matically if large amounts of heat are suddenly
required.
■
"Active cooling mod.": see page 38.
After enabling active cooling mode, a high cooling
capacity is available for centrally cooling your home,
if required.
■
Heating curve/cooling curve: see page 28.
The heating curve enables you to individually adjust
the heating system to the actual heat demand in your
home. If set correctly, your preferred temperature will
be achieved all year round. The same applies to the
cooling curve.
■
"Party mode": see page 29.
Select "Party mode" if you want to heat your home
to a different temperature than the one set in the
time program.
Example: late in the evening, the reduced room tem-
perature is set by the time program. Your guests stay
longer.
DHW heating
■
Time program: see pages 33 and 35.
Use the time program for DHW heating. Adjust the
DHW heating to suit your requirements, so that more
hot water is available in the mornings than during the
day, for example.
Use the time program for the DHW circulation pump.
During the selected time phases, DHW is available
at the draw-off points at the required temperature.
■
"Start optimisation": see page 34.
The start optimisation ensures that your DHW cylin-
der will be heated to the selected temperature at the
beginning of any heating phase.
■
"Stop optimisation": see page 35.
The stop optimisation ensures that your DHW cylin-
der will be heated to the selected temperature at the
end of any heating phase.
■
Once-only DHW heating: see page 35.
With "1x DHW heating" the heat pump will immedi-
ately heat up the DHW cylinder, independent of any
time program.
■
Electric booster heater (if installed): see page 37.
Enable the electric booster heater. Set the time pro-
gram for this. The electric booster heater starts auto-
matically, if the heat pump on its own cannot heat up
the DHW cylinder quickly enough, for example dur-
ing the power-OFF times enforced by the local power
supply utility.
Mechanical ventilation (in conjunction with a venti-
lation unit)
■
"Intensive operation": see page 43.
"Intensive operation" enables you to increase the
air change rate in your home, for example when
cooking.
Quieter operation of air/water heat pumps
■
Quieter operation: see page 39.
Select the time program for quieter operation,
for example in order to reduce the noise level of your
air/water heat pump at night.
Introductory information
Tips for greater comfort
5790940