TSGR-21 GAS Release Panel User Manual
Vighnaharta Technologies Pvt. Ltd. Page 1 of 43
TRUESAFE GAS R E L E A SE PANE L
TSG R -21
USE R MANUAL
Mfg. By:
Vighnaharta Technologies Pvt. Ltd.
2nd Floor,Karanjkar Estate,S.N.11/11,Nanded Gaon,Pune-411041
Contact no.: +919011033259 (Landline) Sales: +919011033260
Email: sales@vighnaharta.in | Website: http://www.vighnaharta.in
Vighnaharta Technologies Pvt. Ltd.
2nd Floor,Karanjkar Estate,
S.N.11/11,Nanded Gaon,
Pune-411041
Tel no.: +919011033259, Sales: +919011033260
Email: sales@vighnaharta.in | Website: http://www.vighnaharta.in
Prepared By: SSK
Approved By: JVG
Doc No.: TSGR-21_UM_1_0
Rev.No.: 1_0
Eff.Date.: 02.09.2020
Question and Answer IconNeed help?

Do you have a question about the Vighnaharta TSGR-21 and is the answer not in the manual?

Summary

Fire Alarm System Limitations

Product Description

Overview

TSGR-21 is used for fire detection and suppression, monitoring gas cylinders and activating solenoid valves.

System Features

Lists features like 24V DC operation, battery backup, LCD display, keypad for configuration, and programmable circuits.

Technical Specifications

Details power supply, input specifications (IDC), and front panel LED/LCD indications.

Controls and Indications

Covers panel controls, LED indicators, LCD display, and buzzer functions.

Components

Lists major components like PCB Board, Power Supply, Enclosure, Battery, and EOL Resistor.

Installation

Installation Precaution

WARNING: Do not attempt to install, service, or operate this unit until this manual is read and understood.

Mounting Details

Provides dimensions and indicates the location for mounting the panel.

Block Diagram of Panel

Shows basic components of TSGR-21 system and their connections to the control panel.

Field Wiring Details

Diagram and table showing connector placement and their connections on the interface board.

Initiating Device Circuit (IDC)

Details the number of initiating circuits, type, wire size, operating voltage, connector, and number of devices.

Output Circuits

Describes the three types of output circuits: NAC, RAC, and PFC Relay Outputs.

Release & Abort controls

Explains digital inputs for release, abort, and remote inputs, with related MCP usage.

Maintenance

Maintenance mode through Key Switch

Explains how to select maintenance mode using a key switch for testing without activation.

Servicing

Provides a checklist for panel servicing, recommended twice a year.

Periodic inspection and test of system

Details weekly testing by the user and other periodic inspections for system functionality.

Dos and Donts

Dos

Provides guidance on taking responsibility, understanding the system, and training people.

Donts

Advises against ignoring recurring problems and allowing apathy to fire alarms.

System Configuration

Programming menu

Details how to enter the programming mode and lists the six main programming menu options.

Program Function

Explains how to navigate menus using keys and describes options for System Config and Input Config.

System Config

Details how to set Date, Time, and view About information (Model, Firmware).

Input Config

Explains how to configure Zone1, Zone2, Pressure Switches, and Actuator switches.

Output Config

Details RAC Configuration options (Z1/Z2 Cross, Z1/Z2, Z1 Only, Z2 Only) and Cylinder Type.

Event View

Explains how to view Fire Alarm Events, Fault Alarm Events, RAC Events, and Sequence of Events.

Timer Setting

Details setting timers for Manual Release, Pre Release, RAC Off, and RAC Abort.

Factory Reset

Explains how to perform Factory Default settings and Clear All Events.

System Operation

Function keys

Covers the panel's function keys including MENU, ACK, navigation, SILENCE, Reset, Enter, and Gas Inhibit.

Normal Mode Operation

Explains system behavior under normal conditions, monitoring for fire and faults.

Fire Condition

Describes how the system reacts when a fire is detected in any zone.

Fault Condition

Details how the system indicates faults visually and audibly, and lists common fault types.

Pre Release Condition

Describes the condition where the pre-release timer starts, warning that RAC is about to release.

RAC Released Condition

Describes the state when the RAC release is completed after the pre-release time is over.

RAC Abort Condition

Explains the condition when an RAC release is aborted, stopping the process.

System Silence

Details how to silence the system, turning off NAC output when it is ON.

System Reset

Explains how to reset the system to recover from fire latch or other conditions.

Zone Disable

Explains how the system ignores input from a disabled zone, even if there is a fire condition.

NAC Operation

Describes how NAC outputs operate based on zone fire conditions or RAC release.

RAC Operation

Covers both automatic and manual operation modes for RAC.

Keypad Enable, Disable and Evacuate

Explains key switch operations for enabling/disabling keypad and performing evacuation.

View History Events

Details the four history event view options: Fire Alarm, Fault, RAC Release/Abort, and Sequence of Events.

Fire Alarm Events

Explains how to view and scroll through saved fire alarm events with time and date.

RAC Release;Abort Events

Details how to view and scroll through saved RAC release and abort events.

Fault Events

Explains how to view and scroll through saved system or fault events.

Sequence of Events

Details how to view and scroll through saved sequence events, excluding Fire, Fault, and RAC events.

Vighnaharta TSGR-21 Specifications

General IconGeneral
BrandVighnaharta
ModelTSGR-21
CategoryFire Alarms
LanguageEnglish