TSGR-21 is used for fire detection and suppression, monitoring gas cylinders and activating solenoid valves.
Lists features like 24V DC operation, battery backup, LCD display, keypad for configuration, and programmable circuits.
Details power supply, input specifications (IDC), and front panel LED/LCD indications.
Covers panel controls, LED indicators, LCD display, and buzzer functions.
Lists major components like PCB Board, Power Supply, Enclosure, Battery, and EOL Resistor.
WARNING: Do not attempt to install, service, or operate this unit until this manual is read and understood.
Provides dimensions and indicates the location for mounting the panel.
Shows basic components of TSGR-21 system and their connections to the control panel.
Diagram and table showing connector placement and their connections on the interface board.
Details the number of initiating circuits, type, wire size, operating voltage, connector, and number of devices.
Describes the three types of output circuits: NAC, RAC, and PFC Relay Outputs.
Explains digital inputs for release, abort, and remote inputs, with related MCP usage.
Explains how to select maintenance mode using a key switch for testing without activation.
Provides a checklist for panel servicing, recommended twice a year.
Details weekly testing by the user and other periodic inspections for system functionality.
Provides guidance on taking responsibility, understanding the system, and training people.
Advises against ignoring recurring problems and allowing apathy to fire alarms.
Details how to enter the programming mode and lists the six main programming menu options.
Explains how to navigate menus using keys and describes options for System Config and Input Config.
Details how to set Date, Time, and view About information (Model, Firmware).
Explains how to configure Zone1, Zone2, Pressure Switches, and Actuator switches.
Details RAC Configuration options (Z1/Z2 Cross, Z1/Z2, Z1 Only, Z2 Only) and Cylinder Type.
Explains how to view Fire Alarm Events, Fault Alarm Events, RAC Events, and Sequence of Events.
Details setting timers for Manual Release, Pre Release, RAC Off, and RAC Abort.
Explains how to perform Factory Default settings and Clear All Events.
Covers the panel's function keys including MENU, ACK, navigation, SILENCE, Reset, Enter, and Gas Inhibit.
Explains system behavior under normal conditions, monitoring for fire and faults.
Describes how the system reacts when a fire is detected in any zone.
Details how the system indicates faults visually and audibly, and lists common fault types.
Describes the condition where the pre-release timer starts, warning that RAC is about to release.
Describes the state when the RAC release is completed after the pre-release time is over.
Explains the condition when an RAC release is aborted, stopping the process.
Details how to silence the system, turning off NAC output when it is ON.
Explains how to reset the system to recover from fire latch or other conditions.
Explains how the system ignores input from a disabled zone, even if there is a fire condition.
Describes how NAC outputs operate based on zone fire conditions or RAC release.
Covers both automatic and manual operation modes for RAC.
Explains key switch operations for enabling/disabling keypad and performing evacuation.
Details the four history event view options: Fire Alarm, Fault, RAC Release/Abort, and Sequence of Events.
Explains how to view and scroll through saved fire alarm events with time and date.
Details how to view and scroll through saved RAC release and abort events.
Explains how to view and scroll through saved system or fault events.
Details how to view and scroll through saved sequence events, excluding Fire, Fault, and RAC events.