10
TAB: 7559
EN
CONFIGURATION STANDBY
CALL / CONVERSATION / SELF-
START / ACTUATIONS CONTEXT
None of P3..P6 congured. P7
not congured.
Aux2
None of P3..P6 congured. P7
congured.
Programmed function in P7
Only one of P3..P6 (Pn)
congured, the others not. P7 not
congured.
Intercom call or alert
programmed in Pn
Aux2
Only one of P3..P6 (Pn)
congured, the others not. P7
congured.
Intercom call or alert
programmed in Pn
Programmed function in P7
At least two of P3..P6 congured.
P7 not congured.
The Intercom context is
shown
Aux2
At least two of P3..P6 congured.
P7 congured.
The Intercom context is
shown
Programmed function in P7
T3 has the function of ringtone mute / mute microphone. The associated LED will operate also as an indicator for:
User absent (the internal unit rejects the call from an outdoor unit and consequently the call is unsuccessful). In
this case the LED ashes at intervals of 0.1 s on and 0.9 s o󰀨.
Ringtone disabled (the internal unit does not ring for calls from the outdoor unit, but otherwise functions normally).
In this case the LED is on steady.
The LED is essential when the display is switched o󰀨.
The C key cannot be programmed and its function is context-dependent.
The P/A
key is used to answer or close a call / conversation. In standby it calls the porter switchboard, if the
management with switchboard is active. Moreover, the LED associated to the P/A key
remains on and switches
o󰀨 briey for 1, 2, 3 or 4 times for each cycle according to the number of calls received and but not answered for any
reason. If there are any missed calls, press the P/A
key for 2 s to reset the call counter. The same can be done by
re-activating the ringtone, after self-start, or after answering a call.
By default, the LOCK
key controls the lock of the last outdoor unit to make a call or the outdoor unit for which self-
start procedure was performed. It can only be programmed using SaveProg. The LED associated with the LOCK
key indicates door open status of the system, essential when the display is switched of, even if the same key is pro-
grammed for another function. In some states (e.g. conversation) the icon also appears in the top right-hand side of
the screen.
In standby mode, the screen is completely switched o󰀨. (In the method described above), by activating any one of the
keys T1..T4 and LOCK
by default the function is performed without switching on the display unless the function
has to do so in order to be performed, such as self-start.
Starting with 7559 in default, the T4 key enables the rst relay in the Due Fili system. It is usually indicated as stair light
or Aux1. When one or more of the other three keys (T1..T3) in the Actuations context is congured, the T4 key does not
act directly but opens the complete menu of keys T1..T4 in the Actuations context.