4 ALARMS DESCRIPTION
ERRORS
ALARMS
Crc alarm indication on the console. It occurs after uploading a
new software version to the motor; to remove the indication on
the console to go on the first page of the alarms and reset all
Low battery indication. The machine stops at the first
intermediate floor until the battery reaches an acceptable
charge level. When the battery is charged, the machine can
resume
Indication of ko motor. The hall sensors which carry out the
motor encoder are faulty. The machine remains locked until the
motor is replaced
Display of SQ2 safety gear microswitch or SQ4 over-run
microswitch activation. The machine starts again when the
activated microswitch is re-enabled. The SQ16 encoder must be
zeroed again to reactivate the stored path
Display of tilt or micro housing or SB0 emergency switch
activation. The machine starts again when the tilt is re-enabled
or the obstacle on the housings is removed or the SB0 emergency
switch is restored.
Indication of closed contact relay. Remove the general board,
replacing it with a new one. The SQ16 encoder must be zeroed
again to reactivate the stored path.