5 TROUBLESHOOTING
CRC
[26]
Load new software (new revision)
Reset the alarm going into the first alarm page and setting everything to zero
Low battery
[12]
Low battery
- The machine goes slow march until it reaches the first
intermediate floor or parking position, where it stops until the battery is
recharged
- check the battery
- if the alarm persists, replace the battery
NB: for more complete troubleshooting, refer to handbook 8885375
Hall Sensor Error
[17]
Motor with faulty encoder
Replace motor
Safety
[61]
Safety gear SQ2 microswitch activation
- Check if the microswitch is pressed
- Check the sheath
NB: for more complete troubleshooting, refer to handbook 8885375
Safety
[61]
Over-run SQ4 microswitch activation
- Check if the microswitch is pressed
- Check the sheath
NB: for more complete troubleshooting, refer to handbook 8885375
Input tilt
[62]
Inclinometer tilt activation
- Check to see if the machine is parallel to the floor
- Check the sheath
NB: for more complete troubleshooting, refer to handbook 8885375
Input tilt
[62]
Rear boards SQCARTER intervention
- Check if the housing is pressed
- Check the sheath
NB: for more complete troubleshooting, refer to handbook 8885375