Page 14 ACM Telephone System – AMC-M-A A100K 10430 v.1.0
4 PROGRAMMING AND CABLE REFERENCE LIST
The ACM-M-A-V2 programming and cable reference list consists of a
set of tables summarizing the main information needed to program an
ACM-M-A-V2 exchange for a vessel.
The standard programming is documented in a Microsoft Excel
Spreadsheet. This sheet should be modified by the customer in
accordance with his needs. This information is then used by the supplier
to perform the programming of the ACM-M-A-V2 exchange.
The exchange is delivered ready programmed, but may be modified by
the customer later on by use of AlphaPro and AlphaWeb programming
tools.
4.1 Station and User Information
Table 3 Station and user information example
4.1.1 Station info
z Directory Number
- The number to dial to reach the station.
The default is successive 3-digit numbers from 101 to 166
z Physical Number
- All stations are identified by the exchange with its physical number.
The first 6 lines on the ASLT12 cards are numbered 1, 2, 3 and so
on up to 36, while the last 6 lines are numbered 277 to 312.
See section 3.5.1 for list of physical numbers.
z Display Text
- The station ID text shown in the called station’s display.
Even if the telephones or intercom stations do not have a display,
this text must be entered as the info is used for other identification
like logging, billing and DECT display.
The default text should normally be substituted by the station
location or the subscriber’s name. The max. number of characters
is 16 including the station directory number.
z Station Type
- Used to define the type of station e.g. DT-800M or TC1020D
STATION AND USER INFORMATION
Programming Terminal connections Additionals Board
Dir.
No:
Phys
No:
Group
member-
ship
Group
Access
Level
COS
Priority
Display text
(Max 12
characters)
Station type: LCM A B C D RCO Information
Ext field
equipment
Pos:
101 1 1 2 5 Wheelhouse TC1020 1 1 1 1K+, 1K- Member ringing group 6701 1
102 2 1 2 5 Wheelhouse TC1020 1 1 1 2K+, 2K- Member ringing group 6701 1
103 3 1 0 1 Station 3 - 1 2 2 3K+, 3K- 1
104 4 1 0 1 Station 4 - 1 2 2 4K+, 4K- 1
105 5 1 2 4 Captain Day TC1020 1 3 3 5K+, 5K- Parallel ringing 1 1
106 6 1 2 4 Captain Bed DT-800M 1 3 3 6K+, 6K- Parallel ringing 1 1
107 277 1 2 3 Chief Eng.Day HSB03 1 4 4 Parallel ringing 2 1
108 278 1 2 3 Chief Eng.Bed DT-800M 1 4 4 Parallel ringing 2 1
109 279 1 0 1 Messroom TC1020 1 5 5 Member ringing group 6701 1
110 280 1 0 1 Hospital DT-800M 1 5 5 1
111 281 1 0 1 Station 11 - 1 6 6 1
112 282 1 0 1 Station 12 - 1 6 6 1
113 7 1 0 1 Station 13 - 1 7 7 7 7 Intercom station 2
114 8 1 0 1 PA monitor VMP-619 1 8 8 8 8 PA monitor station 2
115 9 1 0 1 Station 15 - 1 9 9 9 9 Intercom station 2
116 10 1 0 1 Station 16 - 1 10 10 10 10 Intercom station 2
117 11 1 0 1 Station 17 - 1 11 11 11 11 Intercom station 2
118 12 1 0 1 Station 18 - 1 12 12 12 12 Intercom station 2
119 13 1 0 1 Station 19 - 1 13 13 3
120 14 1 0 1 Station 20 - 1 13 13 3
121 15 1 0 1 Station 21 - 1 14 14 3
122 16 1 0 1 Station 22 - 1 14 14 3
123 17 1 0 1 Station 23 - 1 15 15 3
124 18 1 0 1 Station 24 - 1 15 15 3
125 289 1 0 1 Station 25 - 1 16 16 3
126 290 1 0 1 Station 26 - 1 16 16 3