2-4 PROGRESSIVE DOOR TRIGGER ON/OFF:
The system responds to a door trigger input
with a progressive response. When the door is opened with the system armed, the siren will chirp
10 times prior to the full triggered sequence. The door trigger is still treated as an instant trigger and
closing the door quickly will not prevent a full triggered sequence from occurring. If the progressive
door trigger is programmed off, the full siren output will occur when the door is opened.
2-5 VALET PULSE COUNT ONE TO FIVE PULSES:
The system can be programmed to count
the number presses of the valet button before disarming the security system or VRS
®®
. The factory
default setting is one pulse. The unit can be set for two to five pulses using the two-chirp setting to
select the pulse count.
Ghost Switch Option: For added security, the GRAY wire on the two-pin Valet/Program can be
connected to any switch in the vehicle that provides a positive (+) momentary pulse.
2-6 BYPASS NOTIFICATION ON/OFF:
When programmed On, zone 3 input to the system
during arming will generate a bypass notification chirp, if active. When programmed OFF, no
bypass notification chirps will be generated if zone 3 is active during arming.
2-7 ENHANCED DOMELIGHT CONTROL:
This feature has four possible settings: Full, Door
Controlled, Ignition Controlled, and None. The optional domelight supervision feature
must be installed.These function as follows:
FULL: The system incorporates both Door Controlled and Ignition Controlled features
(described below).
DOOR CONTROLLED: If turned on, a 30-second timer will start after the door has
been opened and then closed. If the door trigger (door open) remains active for longer
than 180-seconds, the timer will not activate for this cycle. If the ignition is activated, the
timer will stop.
IGNITION CONTROLLED: If turned on, the system will turn on the domelight for
30 seconds when the ignition is turned off.
NONE: The system will provide dome light output as a pulsed full trigger output
and for 30-seconds after the system is disarmed.
2-8 DOUBLE/SINGLE PULSE UNLOCK:
Some vehicles require two pulses on a single wire to
unlock the doors. When the double pulse unlock feature is turned on, the BLUE/BLACK H2/F
wire will supply two pulses instead of a single pulse. This makes it possible to directly interface with
double pulse vehicles without any extra parts.

Other manuals for Viper 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viper 3000 and is the answer not in the manual?

Viper 3000 Specifications

General IconGeneral
ModelViper 3000
CategoryCar Alarm
Remote ControlYes
Number of Remotes Included2
Door Lock ControlYes
Trunk ReleaseYes
Panic ModeYes
Valet ModeYes
Remote Start ReadyYes
Range1/4 Mile

Related product manuals