EasyManuals Logo

Vitec Multimedia MGW Ace Decoder OG User Manual

Vitec Multimedia MGW Ace Decoder OG
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
MGW Ace Decoder OG
User Manual, Version 2.0 37
To set the Decoder:
Parameter Description
Decoder
Clock Source
Select source clock either from:
Stream clock
Genlock input clock: Genlock reference input is available from
openGear chassis (REF 1 and REF2) or from MGW Ace Decoder OG
breakout cable.
Do not connect any genlockreference input on the breakout cable if using REF1 or REF2
genlock input.
Original PCR: Original PCR mode ensures a constant latency at startup
and over time.
Stream clock mode is optimized for low latency decoding and provides
compatibility with non- fully compliant TS streams.
Decoder
Buffer Mode
Manual (default)
Time-Synchronized: Compatible with VITEC enabled encoders (MGW Ace
Encoder and MGW Diamond)
Time synchronized playback ensures the playback of the stream after a
defined and fixed latency (End-to-End latency parameter).
As such, it allows to synchronize multiple independent decoders when the
End-to-End latency parameter is set at the same value.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vitec Multimedia MGW Ace Decoder OG and is the answer not in the manual?

Vitec Multimedia MGW Ace Decoder OG Specifications

General IconGeneral
BrandVitec Multimedia
ModelMGW Ace Decoder OG
CategoryMedia Converter
LanguageEnglish

Related product manuals