EasyManua.ls Logo

Vivotek FD7132 - Drive the Digital Output; Query Status of the Digital Input

Vivotek FD7132
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK - A Leading Provider of Multimedia Communication Solutions
106 - User's Manual
Drive the digital output
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0, 1. “0” means inactive or normal state while “1” means active or triggered
state.
PARAMETER VALUE DESCRIPTION
0 – inactive, normal state
do<num>
0, 1
1 – active, triggered state
return
<return page> Redirect to the page <return page> after the parameter
is assigned. The <return page> can be a full URL path or
relative path according the the current path. If you omit
this parameter, it will redirect to an empty page.
Example: Drive the digital output 1 to triggered state and redirect to an empty page
http://myserver/cgi-bin/dido/setdo.cgi?do1=1
Query status of the digital input
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <length>\r\n

Other manuals for Vivotek FD7132