10TA Service Manual
INSTALLING YOUR TUBE-ICE
®
MACHINE
4/14/14
3-9
Ice Machine Model 10TA
Electrical Frequency, Hz. 60 50
Recommended Condenser BNHS04A029
Total Heat Rejection (BTU/hr) 427,500 393,300
Fans:
Number
HP, Each
Total CFM
4
1 1/2
38,600
4
1 1/2
38,600
Full Load Amps (FLA):
3 ph., 208/230V, 60 hz.
3 ph., 460V, 60 hz.
3 ph., 200V, 50 hz.
3 ph., 380V, 50 hz.
28.0
14.0
--
--
--
--
28.0
14.0
Weight, lbs.:
Net
Shipping
Operating (Maximum flooded) R-404a
1210
1520
1265
Condenser Dimensions, inches (See Fig. 3-7)
A (Width)
B (Length)
C (Height)
D (Leg centerline)
E (Leg centerline)
F (Clearance below)
45.46”
233.16”
49.15”
38”
106.15(3)”
20.5”
Recommended Line Sizes, OD
Liquid
All lengths and orientations
Discharge Gas
Vertical Up, all lengths
Horiz. or Down, < 75 ft.
Horiz. or Down > 75 ft.
1 3/8”
1 5/8”
1 5/8”
2 1/8”
Connections (Condenser):
Liquid (ODF)
Discharge Gas (ODF)
1 3/8”
2 1/8”
1 1/8”
1 3/8”
Connections (Ice Machine):
Liquid (ODF)
Discharge Gas (ODF)
TABLE 3-4