58
Alternating current
Range Resolution Accuracy*
600.0 A 0.1 A ±(1.5% + 10)
1000 A 1 A ±(1.5% + 10)
Frequency range: 50 - 60 Hz; Overload protection: 600 V, 1000 A
*Measuring position error: Accuracy deviation for non-centred measurement position: +1%
*Accuracy: 40 - 60% of the measurement range; +(1.5% ± 10) outside of this range
TrueRMS crest factor (CF) for non-sinusoidal signals: max. 3.0
CF >1.4 - 2.0 + 1%
CF >2.0 - 2.5 + 2.5%
CF >2.5 - 3.0 + 4%
Direct current (VC-533 only)
Range Resolution Accuracy*
600.0 A 0.1 A ±(2.8% + 8)
1000 A 1 A ±(2.8% + 8)
Overload protection 600 V, 1000 A
*Measuring position error: Accuracy deviation for non-centred measurement position: +1%
*Accuracy: 40 - 60% of the measurement range; +(1.5% ± 10) outside of this range
AC voltage
Range Resolution Accuracy*
6.000 V 0.001 V
±(1.5% + 5)
60.00 V 0.01 V
600.0 V 0.1 V
600 V 1 V
Frequency range: 50 - 100 Hz; Overload protection: 600 V; Impedance: 10 MΩ
*Accuracy: 40 - 60% of the measurement range; +1% outside of this range
TrueRMS crest factor (CF) for non-sinusoidal signals: max. 3.0
CF >1.4 - 2.0 + 1%
CF >2.0 - 2.5 + 2.5%
CF >2.5 - 3.0 + 4%