Frequency “Hz”
Range Resolution Accuracy
5 - 9.999 Hz 0.001 Hz
±(1.5% + 6)
99.99 Hz 0.01 Hz
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
Signal level: > 8 Vrms
*Accuracy: 40 - 60% of the measurement range; +1% outside of this range
Pulse ratio “%”
Range Resolution Accuracy
20.0 - 80.0% 0.1% ±(1.5% + 4)
Frequency range: 5 Hz - 10 kHz, Signal level: >8 Vrms
Displays the positive half-wave in %
Diode test
Test voltage Resolution
Approx. 3.3 V 0.001 V
Overload protection: 600 V; Test voltage: <1.3 mA
Acoustic Continuity tester
Test voltage Resolution
Approx. 1 V 0.1 Ω
Overload protection: 600 V, Measurement range max. 600 Ω;
Continuous tone <50 Ω, No tone ≥50 Ω
Test current: <0.5 mA
Response time 1 ms
NCV non-contact AC voltage test
Test voltage Distance
>230 V/AC max. 50 mm
Frequency: 50 - 60 Hz
Never exceed the maximum permitted input values. Never touch circuits or parts of circuits when
they may contain voltages greater than 33 V/ACrms or 70 V/DC! Fatal hazard!