Alternating voltage
Range Accuracy Resolution Frequency range
4 V
±(0.5 % + 40 digits)
0.0001 V
45 – 1,000 Hz
±(1.2 % + 40 digits) 1,000 – 10,000 Hz
±(3 % + 40 digits) 10,000 – 20,000 Hz
±(4 % + 40 digits) 20,000 – 100,000 Hz
40 V
±(0.5 % + 40 digits)
0.001 V
45 – 1,000 Hz
±(1.2 % + 40 digits) 1,000 – 10,000 Hz
±(3 % + 40 digits) 10,000 – 20,000 Hz
±(6 % + 40 digits) 20,000 – 100,000 Hz
400 V
±(0.5 % + 40 digits)
0.01 V
45 – 1,000 Hz
±(1.2 % + 40 digits) 1,000 – 10,000 Hz
±(3 % + 40 digits) 10,000 – 20,000 Hz
N/A 20,000 – 100,000 Hz
600 V
±(1.2 % + 40 digits)
0.1 V
45 – 1,000 Hz
±(3 % + 40 digits) 1,000 – 10,000 Hz
±(6 % + 40 digits) 10,000 – 20,000 Hz
N/A 20,000 – 100,000 Hz
Overload protection: 1000 V; Impedance: about 10 Mȍ
TrueRMS in the measuring range of 10 – 100%; Crest factor: max. 3.0 (at 750 V max. 1.5)