Maintenance
78 Maintenance every 1000 operating hours
Maintenance every 1000
operating hours
Change the engine oil
Oil change intervals
– The oil change intervals depend on the use of the wheel loader
and the quality of the lubrication oil.
– If the oil change intervals are not reached within a year, the oil
change must be performed at least 1x year.
– When using fuels with a sulphur content of > 0.5 to 1% or when
working permanently at ambient temperatures below -10 °C
(+14 °F) the oil change intervals must be halved.
– For fuels with a sulphur content higher than 1% you should con-
sult the service agent responsible for you.
Engine oil change
Perform the oil change when the engine is warm and shut
down (lubrication oil temperature approx. 80 °C / 1 76 °F).
– Unscrew the cap from drain valve (A).
– Screw the drain hose (B) onto the drain valve.
– Screwing the drain hose on opens the drain valve and allows
the oil to flow out.
– Once all old oil has run out unscrew the drain hose and screw
the cap back on the drain valve .
– Fill the new oil in through the filler neck only up to the top dip-
stick mark (Max.).
Oil filling quantity including filter approx. 10.5 litres / 2.8 US
gal, for quality of oil refer to the table of lubrican ts.
– Check the oil level after a short test run (2 minutes at low idle),
if necessary top up to the top mark (Max.).
ATTENTION!
Hot oil - danger of scalding!
Catch running out oil and dispose of environmentally.
M200088
A
max
min
OIL
M200069A
A
B